Commit graph

517 commits

Author SHA1 Message Date
Carlos Garnacho
71945b8156 wacom: Clear background on "target" actor in calibration UI
the actor's draw() method isn't guaranteed to get a pristine surface,
which may cause artifacts if the background is left untouched, so
clear the background each time the actor has to be drawn.

https://bugzilla.gnome.org/show_bug.cgi?id=719701
2013-12-16 12:30:24 +01:00
Carlos Garnacho
fdef36294a wacom: Set several notebooks' show-border property to FALSE
Since GTK+ commit 05b1ea84b, this hint is used in GtkNotebook to add
a GTK_STYLE_CLASS_FRAME when rendering the notebook frame, so the theme
renders those frame-alike. As it's not what we want for the wacom panel,
set show-border to FALSE on all GtkNotebooks.

https://bugzilla.gnome.org/show_bug.cgi?id=710709
2013-12-02 12:29:30 +01:00
Yosef Or Boczko
ae36409c5f wacom: Use margin-start/end instead of margin-left/right
https://bugzilla.gnome.org/show_bug.cgi?id=712661
2013-11-19 22:34:39 +02:00
Jasper St. Pierre
dd52ac9417 Add NoDisplay to all gnome-control-center panel .desktop files
These aren't apps -- they're simply launchers for gnome-control-center.
They should not be shown as apps in the UI at all.

https://bugzilla.gnome.org/show_bug.cgi?id=712246
2013-11-15 08:44:53 -05:00
Bastien Nocera
8d7402c04e wacom: Fix slider on Inking Pen page
https://bugzilla.gnome.org/show_bug.cgi?id=711326
2013-11-03 15:05:33 +01:00
Bastien Nocera
95f613bee1 wacom: Fix ~100 pixel offset when calibrating
The calibration gui code moved the targets to x,y, instead of
placing the centre of the target at x,y, leading to a 47 pixel
(half the target's size) offset in both directions (thus 67 pixels
deviation as Pythagorus would tell us).
2013-10-09 12:55:29 +02:00
Bastien Nocera
bf68dfb62d wacom: Fix comment for timeout duration
The comment mentioned 5 seconds, but we use 15 seconds.
2013-10-09 12:18:48 +02:00
Bastien Nocera
18dd6ff04f wacom: Fix incorrect default window information
The window isn't 1x1...
2013-10-08 20:15:55 +02:00
Bastien Nocera
7be584f4f9 wacom: Update from gnome-settings-daemon 2013-10-08 19:25:01 +02:00
Bastien Nocera
297eb6cfbb wacom: Fix use after free
Causing random values in the calibration data.
2013-10-08 18:59:22 +02:00
Bastien Nocera
8e1dd1ae5d wacom: Update from gnome-settings-daemon 2013-10-08 18:55:19 +02:00
Bastien Nocera
4c2c93c01f wacom: Update from gnome-settings-daemon 2013-10-08 18:31:39 +02:00
Bastien Nocera
6aa409ffdb wacom: Reset the calibration before starting a new one
We shouldn't be using the old calibration values to create the
new ones, so reset the "area" settings before starting a new
calibration, and re-apply the saved calibration if the calibration
is cancelled or fails.

https://bugzilla.gnome.org/show_bug.cgi?id=707784
2013-10-08 18:02:43 +02:00
Bastien Nocera
21a2a53fea wacom: Update from gnome-settings-daemon 2013-10-08 17:59:12 +02:00
Bastien Nocera
c9864b1ebc wacom: Fix event filtering in the calibrator
We were always getting the events from the core pointer instead
of the device itself, so threw all of them away.
We need to get the real source device from the event.

https://bugzilla.gnome.org/show_bug.cgi?id=707784
2013-10-08 11:48:13 +02:00
Bastien Nocera
054538c292 wacom: Add some more debug to the calibrator tool 2013-10-04 11:16:45 +02:00
Bastien Nocera
55744f6544 wacom: Fix device filtering in calibration UI
We receive ClutterEvents, not GdkEvents for button presses on
ClutterActors, so use the correct functions to filter devices.

This also fixes the offset used to access the coordinates of the
events. We were actually using the pointer to the source and x
struct members instead of x and y.

https://bugzilla.gnome.org/show_bug.cgi?id=707784
2013-10-04 11:16:45 +02:00
Bastien Nocera
387e3f98f7 wacom: Print debug when calibration is finished 2013-10-04 11:16:45 +02:00
Bastien Nocera
752c964c1c wacom: Align the stylus section with the tablet section
https://bugzilla.gnome.org/show_bug.cgi?id=709360
2013-10-04 09:09:34 +02:00
Giovanni Campagna
77c72eb8ce wacom: adapt to GnomeRR API changes
GnomeRR now returns the EDID IDs as strings directly, so we don't
need to convert them to compare to the settings. Also, we don't
need to filter disconnected outputs, it's done by mutter now.

https://bugzilla.gnome.org/show_bug.cgi?id=705573
2013-08-19 09:58:05 +02:00
Bastien Nocera
c3c2b23487 wacom: Fix possible use before set 2013-07-30 16:42:23 +02:00
Joaquim Rocha
d83e0ff5c1 wacom: Call the OSD window for assigning the tablets' buttons
It falls back to the listbox view in case the OSD cannot be shown.

https://bugzilla.gnome.org/show_bug.cgi?id=704798
2013-07-26 20:04:35 +02:00
Joaquim Rocha
83fdff79bb wacom: Add missing cc-wacom-button-row 2013-07-24 14:42:20 +02:00
Joaquim Rocha
df161dba18 wacom: Use a GtkListBox for the buttons' mapping instead of a GtkTreeView
https://bugzilla.gnome.org/show_bug.cgi?id=703148
2013-07-24 11:18:24 +02:00
Joaquim Rocha
afea7e93f0 wacom: Update from gnome-settings-daemon 2013-07-24 11:18:24 +02:00
Joaquim Rocha
d125505266 wacom: Add gsd-wacom-key-shortcut-button to be updated from g-s-d 2013-07-24 11:17:06 +02:00
Yosef Or Boczko
cf81bc227f wacom: drop GtkStock
https://bugzilla.gnome.org/show_bug.cgi?id=704178
2013-07-19 15:59:26 +03:00
Joaquim Rocha
35e3697b1d wacom: Expand columns in buttons' assignment treeview
Because the GtkCellRendererAccel can't almost be seen.

https://bugzilla.gnome.org/show_bug.cgi?id=703043
2013-07-17 15:51:47 +02:00
Joaquim Rocha
97648fe80c wacom: Reduce white-space between tablet and styli controls
https://bugzilla.gnome.org/show_bug.cgi?id=698119
2013-07-15 18:41:23 +02:00
Przemo Firszt
3708eab09d wacom: Show hard-coded action names on OLED too
Show hard-coded action names on OLED as well, not just
for custom actions.

https://bugzilla.gnome.org/show_bug.cgi?id=700498
2013-07-15 18:39:02 +02:00
Joaquim Rocha
edc0a9b11f wacom: Fix discrepancy when switching monitors from g-c-c
The rotation was being set directly from g-c-c when switching
monitors but g-s-d already does this when the display is set to
the tablet. This resulted in a discrepancy between setting the
monitor from g-c-c or from g-s-d when the left-handed mode was on.

https://bugzilla.gnome.org/show_bug.cgi?id=700439
2013-06-10 11:06:43 +02:00
Joaquim Rocha
48164b5a3f wacom: Fix segfault when trying to check if the tablet has a monitor
The check method had been changed in order to use the CcWacomPage
instead of its private struct but one of the calls to it wasn't updated.
2013-06-06 15:32:41 +02:00
Joaquim Rocha
366fd4ba94 wacom: Add command line support for calibration
https://bugzilla.gnome.org/show_bug.cgi?id=692816
2013-06-05 18:29:40 +02:00
Joaquim Rocha
ed3c9badff wacom: Add cc_wacom_page_calibrate and cc_wacom_page_can_calibrate functions
https://bugzilla.gnome.org/show_bug.cgi?id=692816
2013-06-05 18:29:40 +02:00
Joaquim Rocha
e45bafaacb wacom: Add command line argument support for choosing the tablet
https://bugzilla.gnome.org/show_bug.cgi?id=692816
2013-06-05 18:29:40 +02:00
Rui Matos
e87c4ad340 wacom: Set button arrow icons according to locale's text direction
https://bugzilla.gnome.org/show_bug.cgi?id=700543
2013-06-05 11:27:34 +02:00
Joaquim Rocha
d78bc9772a wacom: Re-write gui_gtk in Clutter to introduce animations
The name of the file was also changed to calibratorgui.c/h to avoid
it being inconsistent, this way it is no longer dependent on the
the technology.

https://bugzilla.gnome.org/show_bug.cgi?id=667797
2013-05-17 16:36:59 +02:00
Joaquim Rocha
3cf0addbfe wacom: Do not unref variant consumed by GSettings
This avoids a critical warning.

https://bugzilla.gnome.org/show_bug.cgi?id=700511
2013-05-17 16:18:43 +02:00
Bastien Nocera
3968797027 wacom: Update from gnome-settings-daemon 2013-05-17 09:39:18 +02:00
Przemo Firszt
16c0a66acf wacom: Add basic OLED handling for Intuos4
This sets the OLED to the keyboard shortcut when a
custom keyboard shortcut is used.

https://bugzilla.gnome.org/show_bug.cgi?id=671072
2013-05-17 09:38:30 +02:00
Joaquim Rocha
2b34736ea8 wacom: Set the last-calibrated-resolution key after calibrating
So g-s-d will know if calibration is needed when the monitor resolution
changes.

This is related to https://bugzilla.gnome.org/show_bug.cgi?id=677095
2013-05-16 11:26:29 +02:00
Joaquim Rocha
3702a56793 wacom: Show the cursor in the calibrator UI when used from test_wacom
This functionality is dictated by the definition of FAKE_AREA in the
CPPFLAGS.
2013-04-16 14:44:08 +02:00
Joaquim Rocha
19876f84d9 wacom: Create a similar calibrator library for testing purposes
This is so we can e.g. add different parameters when creating it
2013-04-16 14:44:08 +02:00
Joaquim Rocha
c74a65acb5 wacom: Prevent failure when device's area cannot be retrieved
It also uses fake data from the screen's area. This functionality is
dictated by the definition of FAKE_AREA in CPPFLAGS.

https://bugzilla.gnome.org/show_bug.cgi?id=689686
2013-04-16 14:44:08 +02:00
Joaquim Rocha
9031c41784 wacom: add a link to the mouse settings panel
Based on previous work by Olivier Fourdan.
2013-04-16 12:33:16 +02:00
Bastien Nocera
176990945e wacom: Update from gnome-settings-daemon 2013-03-04 12:53:22 +01:00
Ángel Guzmán Maeso
1f57add30f wacom: Fix deprecated functions in gui_gtk.c
From gtk_icon_info_free() to g_object_unref()
gtk_window_set_opacity() to gtk_widget_set_opacity()

https://mail.gnome.org/archives/commits-list/2013-February/msg02049.html

https://bugzilla.gnome.org/show_bug.cgi?id=694362
2013-02-21 17:08:26 +01:00
Allan Day
1f7c292122 wacom: Update panel comments
Very few of the panel comments provide information that is very
useful. Update them to supplement the panel descriptions - this
will make the search results more helpful.

https://bugzilla.gnome.org/show_bug.cgi?id=694110
2013-02-19 10:41:43 +01:00
Olivier Fourdan
1f42956437 wacom: small code clean-up
we already set a local variable so better use it, it helps with
code readability.

https://bugzilla.gnome.org/show_bug.cgi?id=689684
2013-01-17 11:06:02 +01:00
Cosimo Cecchi
8d5f2908b5 panels: add --sourcedir=$(srcdir) when generating resource list
Like b8e93fb333 but for all panels.
2013-01-07 16:23:57 -05:00